4kV Flash Tester
Metrohm
E3640
Power Requirement:
115/230 Volts ±15% 50/60Hz 40VA
Fuses:
230V - 5x20mm 0.25A, HBC, Type F
115V - 5x20mm 0.5A, HBC, Type F
Output Voltage Range:
0 - 2.2, 0 - 4.2kV 50/60Hz
Output Voltage Accuracy:
± 2% of reading ± 1 digit
Leakage Current: 0 - 5 mA
(nominal) 50/60Hz in 10μA steps
Leakage Current Accuracy:
±2% of reading ± 1 digit
Trip Level Range: 0 to 3mA 50/60Hz
Setting Accuracy:
±5% of full range
Trip Response Leakage: Will trip
for fault duration >5mS but not for
<100μS
Breakdown: Will trip for fast
transients of 30μS and above
Complies with: EMC: To BS EN
50081-1 and BS EN 50082-2
Safety & Flash Test: BS EN 61010-1
Dimensions: 330 x 263 x 144mm
Weight: 4000g approx
Includes: flash gun, earth lead,
mains power lead and manual
This digital flash tester is a portable mains operated
instrument, capable of operating from either 115V or
230V supplies at 50/60Hz. It can apply up to 4kV AC
and displays both output voltage and leakage current
on the twin 3½ digit LCD’s.
The fail lamp illuminates and the buzzer sounds in the
chosen modes:
Trip - will trip when pre-determined current is
exceeded;
Breakdown - fast transients can trigger the trip;
Burn - where the trip function is by-passed and the
fault current flows continuously to expose the fault;
Hold shows the breakdown voltage and the leakage
current.
Insulation Resistance Range:
100kΩ to 100GΩ
Insulation Range Accuracy:
±1.5% of scale length
Insulation Range Temperature
Coefficient: <0.04% of scale
length/°C
Voltage Range:
1000 volts AC or DC
Voltage Range Accuracy:
±1.5% of scale length
Test Voltages:
500V, 1kV, 2.5kV, 5kV DC
Test Voltage Accuracy:
±5% at 10MΩ
Break Point Current: 0.5mA
nominal
Short Circuit Current: 1.2mA
nominal
Ripple Voltage: <10V peak to peak
(R<10MΩ)
Housing: yellow ABS, black & clear
polycarbonate
Dimension: 330 x 263 x 144mm
Weight: 4200g approx (incl batteries)
Includes: 2m test leads & crop
clips, accessory bag
Having both battery and mains operation and four
selectable DC test voltages (500V, 1kV, 2.5kV & 5kV),
this tester measures insulation resistance from 100kΩ
to 100GΩ. The large, clear analogue scale also
displays AC or DC voltage up to 1000V. Latching test
switch allows hands free testing.
With full over-voltage and over-current protection for
measurements and 4-16 hours operation from re-
chargeable NiMH batteries, the E3511 comes
complete in a rugged carry case. Standard
accessories include locking 2m test leads with prods
and clips.
METE3640 4kV flash tester £975.00
TC2D calibration £72.00
METE3511 5kV insulation tester £1175.00
TC2D calibration £72.00
METDFK0075/A replacement 2m test leads £140.00
METDFK0075/C optional 10m test leads £175.00